Water heater repair in Wolcott, Prospect and Cheshire
No hot water? First checks for tank, tankless and boiler-fed heaters
No hot water starts with one question: what kind of heater do you have? An electric tank, a gas tank, a tankless unit and an indirect tank fed by your boiler each stop for different reasons, and each maker’s own manual starts with a different short list of things that are safe to look at.
This page goes heater by heater, safe checks first, then the point where it becomes a water heater repair call for homes in Wolcott, Prospect and Cheshire. It does not tell you to light, clean, open or replace anything on a gas or electric heater. If you smell gas, leave the house and call your gas company or 911 from a neighbor’s home, as Connecticut PURA advises.
Takeaways
- On an electric tank, both A. O. Smith and Rheem put the breaker or fuse first on their no-hot-water lists (A. O. Smith, Rheem).
- The red high-limit reset button is where the makers part ways: A. O. Smith tells owners how to press it, while Rheem says a qualified technician must investigate the cause first.
- On a tankless heater, read the display code first. Navien’s manual says an owner can try a reset with the Back button; Rinnai’s says consumers should never attempt actions they are not qualified to perform (Navien, Rinnai).
- On an indirect heater, Bradford White’s troubleshooting guide begins with the boiler: if the boiler does not run, the tank has nothing to draw. Call 203-756-5040.
Start with the heater you have
Read the model off the label on the heater and have it ready. Then find your row. The first column is what is safe to look at. The second is where we stop you, and the sections below give each maker’s own wording so you can check us.
| Heater | Safe to check | Service call when |
|---|---|---|
| Electric tank | The breaker or fuse. The temperature setting. Whether the red high-limit button has tripped (see the disagreement below). | The breaker or the red button trips again, or the power is on and the water stays cold. Elements, thermostats and wiring are service parts. |
| Gas tank | Any gas smell, which means leave. The temperature dial. Whether a heavy draw just used up the tank. | The pilot will not stay lit, the burner will not light, or the problem is anything inside the burner compartment. |
| Tankless | The display code. One reset where the manual allows it. A fully open hot tap. Snow or ice at the vent outside. | The same code returns, or the code names gas, ignition, flame or venting, or nothing happens and no code shows. |
| Indirect, off the boiler | Is the boiler on and heating the house? Is its switch on? | The boiler is running and the tank is still cold, or a circulator, zone valve or high limit is the suspect. |
Electric tank: breaker first, then the red button
Both makers start the no-hot-water list in the same place. A. O. Smith’s use and care guide lists “No power to heater” and the action “Check for blown fuses or tripped breaker”. Rheem’s manual for its electronic-control electric heaters (AP21980) lists a blown fuse or tripped breaker with the fix “Replace fuse or reset circuit breaker.” It also lists a thermostat set too low, an electric supply that is off, and open hot water faucets.
A breaker that trips again is not a reset problem. Bradford White’s electric water heater service manual, written for technicians, says an element shorted to ground “will in most cases cause the circuit breaker in the service panel to open or shut off”. And before anyone touches a panel, A. O. Smith’s no-hot-water page says to “Turn off power at the circuit breaker before touching anything.”
The temperature setting on a standard electric tank sits behind a metal access cover with insulation folded over it, and A. O. Smith’s guide walks through removing it. Checking it means opening a panel on a live appliance, so switch the breaker off first, or tell us what the heater is doing and let us look. The scald risk is real. The same guide says “There is a hot water scald potential if the thermostat is set too high.”
The red reset button: two manufacturers, two answers
A. O. Smith says “The high limit control can be reset by firmly pushing in the red reset button located on the thermostat.” Its steps begin “Disconnect the electric power.” Rheem says the control opens when the water gets too hot and that “The cause of the high temperature condition must be investigated by qualified service technician and corrective action must be taken before placing the water heater in service again.” The two manuals disagree, and we are not going to pick one for you. If you do press it, press it once with the power off. If it trips again, stop and call. A. O. Smith agrees on that last part: “If the high limit control switch continues to shut-off the water heater contact a qualified person for service.”
Why the second trip matters: Bradford White’s manual says “Repeated actuation of the ECO is usually the result of a grounded element.” ECO is the maker’s name for the high-limit cutoff. A. O. Smith’s own page puts it the same way for owners, saying repeated tripping points to “shorted elements or faulty thermostats”.
One more rule from both manuals, and it matters after a leak or a drained tank. Rheem says never to turn the heater on unless it is filled with water, and A. O. Smith says “Do not turn on power to the water heater unless it is completely filled with water.”
That is where a service call starts. Bradford White’s service manual says “Most common cause for improper electric water heater operation can be linked to heating element failure.” The manual’s own plan for a technician runs in order: confirm service voltage and that the high limit has not tripped, test the elements, then test the thermostats. None of it is a job to learn on your own heater.
Gas tank: look at the dial and the smell, then call
Gas first. Connecticut PURA says “If the smell is strong or you are unsure, leave the building and then call.” It also says “NEVER turn the gas back on once it has been shut off due to a safety concern. Call your local gas company for assistance.” The Consumer Product Safety Commission lists headache, dizziness, weakness and nausea among the symptoms of carbon monoxide poisoning, and says if you suspect it, get outside to fresh air immediately and then call 911.
With no smell and no alarm, the safe look is at the temperature dial. Rheem’s manual for its gas tank heaters (AP23059) lists a gas control set too low among the causes of not enough or no hot water, and its table also lists a heavy draw: “Wait for the water heater to recover after an abnormal demand.” Rheem’s manual puts the gas control near the bottom of the tank and marks the dial rim at about 120 degrees. Moving the dial is the adjustment the manual describes for owners. The gas control behind it is not.
Rheem’s chart also says the pilot may be out and to relight it from the lighting instructions. We would rather you did not, and the same chart shows why. A pilot that will not stay lit is sent to a qualified technician (a loose or defective thermocouple, a defective safety magnet, a tripped combustion shutoff device), and the chart closes with “For your safety DO NOT attempt repair of gas piping, gas control (thermostat), burners, vent connectors or other safety devices. Refer repairs to qualified service personnel.” A. O. Smith’s page tells owners to clean a clogged burner. We part company with that, and it agrees on the valve: “This component requires precise calibration and should be inspected and replaced by a professional if found to be defective.”
Some gas heaters shut themselves down on purpose. Bradford White’s service manual for its Defender Safety System heaters says the safety switch “also deactivates the burner and pilot in the unlikely event of restricted airflow caused by severe lint, dust, or oil accumulation on the arrestor plate”, and its chart puts the reset button on an inner door of the heater. We do not ask homeowners to open that door. A heater that shuts down and will not relight is a call, with the make and model ready.
Not sure which heater you have, or what it is doing?
Tell us the type, the model on the label and what you see. If it sounds like something that can wait for morning, we will say so.
Tankless: read the code, try one reset, then call
A tankless heater tells you what it thinks is wrong. Navien’s user manual for the NPE heaters says “If an error message appears, you can try resetting the water heater to resolve the problem.” The reset is a press of the Back button. If that does not clear it, the manual says to “contact an authorized technician, a licensed professional, or Technical Support”. Rinnai’s installation and operation manual puts a warning over its code table: “Some of the checks below should be performed by a licensed professional. Consumers should never attempt any action that they are not qualified to perform.”
Two checks cost nothing. Navien’s chart asks whether the set temperature is too low and whether the hot tap is open wide enough to draw at least 0.5 gallons per minute. Rinnai’s no-code line says the same thing from the other side: “Verify you have at least the minimum flow rate required to fire unit.” A tap opened a crack may not move enough water to start the burner.
In a Connecticut winter there is one more, and it is outside. Rinnai’s maintenance section says “Keep the area around flue terminal free of snow and ice.” The heater will not function properly, it adds, if the combustion air or exhaust pipes are blocked. Look at the vent terminal on the outside wall from where you stand. If it looks blocked, tell us.
The codes are where the makers’ lists show how fast a tankless call turns into gas and venting work. Here is what each maker’s own table says for the codes we hear about most.
| Code | What the maker calls it | First line of the maker’s list | Our note |
|---|---|---|---|
| Rinnai 11 | No Ignition (Heater Not Turning On) | “Check that the gas is turned on at the water heater, meter, or cylinder.” | Tell us the code. The rest of the list is gas pressure, igniter and flame rod work. |
| Rinnai 12 | No Flame | The same gas check, then the flame rod wire and inlet gas pressure. | Same: a call. |
| Rinnai 10 | Air Supply or Exhaust Blockage/Condensate Trap is Full | Condensate line, internal air filter, then vents and fan. | Look outside at the vent. The rest is a call. |
| Navien E003 | Ignition failure | “Ensure that the main gas supply valve is open.” | We would rather hear the code than have you work a gas valve. |
| Navien E012 | Flame loss | “Clean the intake air filter.” Then confirm the cord is grounded. | A call. |
| Navien E016 | Overheating of heat exchanger | Clean the cold water inlet filter, then flush the heat exchanger. | Scale is a service item. A call. |
The makers are plain about the limit. Navien’s support page answers a homeowner who asks for help: “there is only a limited amount of troubleshooting that can be done with a homeowner/end-user”. Rinnai’s separate diagnostic codes guide opens with “Only trained and qualified professionals are permitted to follow the instructions in this document.” and warns “DO NOT adjust the internal gas valve.” The Rinnai flame check on code 11 is the technician’s own: “Visually inspect the burner flame through the view glass.”
Boiler-fed indirect heater: check the boiler first
An indirect heater stores hot water in a tank and gets its heat from the boiler, as our indirect vs. tankless guide explains for buyers. That guide is the buying side and this page does not repeat it. This is the repair side, and it starts somewhere simple: the tank can only be as hot as the boiler makes it.
Bradford White’s troubleshooting guide for its double-wall indirect-fired heaters lists causes of no hot water at the faucet in this order. The first is “Boiler does not operate”, and the fixes begin with the boiler’s own instructions, its main service switch and the fused disconnect. Then it lists a circulator that is not running, a tripped high limit on the tank thermostat, a wrong thermostat setting, a zone valve that does not open, an electrical fault, scale on the coil and a clogged strainer.
| Cause the manual lists | Who deals with it |
|---|---|
| Boiler does not operate. Check the main service switch. | You can look at the boiler’s switch and the thermostat call. Anything inside the boiler is ours. |
| Circulator does not operate | Ours. A circulator is wired and piped into the system. |
| Tank thermostat high limit tripped (red reset button) | The same split as on an electric tank: the manual says to determine the reason for the trip first. |
| Zone valve does not open, wiring or relay problem | Ours. |
| Scale on the coil, clogged cold water strainer | Ours. The manual says the coil may be scale-coated when the boiler, circulator and tank all run well. |
It is a zone like any other. Bradford White’s manual says “The indirect-fired water heater must be installed as a zone separate from the space heating system.” So if one room or one zone is cold and the hot water is fine, our one heating zone guide is the right read, and if the whole house is cold, start with boiler running but the house is cold.
Not enough hot water, as opposed to none, has its own rows. Bradford White lists “Undersized boiler with no priority to domestic hot water”, among others, with the fix of rewiring for priority. Lochinvar’s manual for its Squire indirect tanks has a start-up check for exactly this connection: “Make sure that the boiler shuts down when the indirect water heater is satisfied.” Its own scope is clear, too. It says it “must only be used by a qualified heating installer / service technician”. The one owner task it lists is a monthly look: “Visually check valves, pipes, and fittings for leaks. Call a qualified service technician to repair leaks.”
Rust, a leak at the base or a noisy element: when it is a replacement talk
Three signs get people thinking about a new heater. The manufacturers do not say the same thing about all three, so here is what each one actually says.
A leak at the bottom of the tank
This is the one that points to replacement. Rheem says “Leaks from the bottom often signal tank corrosion that requires replacement.” (Rheem, what to do before calling a plumber). A. O. Smith’s page agrees: “if the tank itself is leaking, the entire water heater usually needs to be replaced”. The same page warns that condensation on a gas heater is sometimes mistaken for a leak, so look closely at where the water comes from. Rheem’s article suggests you “photograph any visible leaks, rust, or unusual condensation around the tank” before you call.
Rusty water
Do not condemn the heater on color alone. A. O. Smith’s technical bulletin 21 on discolored water says “it is a rare occurrence for today’s high quality glass lined tanks to have a lining failure significant enough to allow water to contact enough bare metal to discolor the contents of even a small tank”. It says the most common cause of rusty water is a “non-toxic iron reducing bacteria”, and adds that the bacteria can wear out the anode rod early. So the useful question is where the rust shows up and whether the anode rod needs a look. Tell us if it is in the hot taps only or in the cold too.
A pop, hiss or sizzle
On an electric tank, A. O. Smith ties “crackling, popping or hissing sounds” to scale on the heating elements, and Bradford White’s manual lists noisy elements as lime on the elements to be cleaned or replaced. That is an element visit, not an automatic new heater. On a gas tank, Rheem says “Drops of water falling on the burner can produce a sizzling or pinging sound.” and that new-fill condensation is normal; condensation that keeps going is a reason to check the piping for leaks.
Age is what turns a repair into a replacement conversation. Rheem says “If your unit is close to or over 10 years old and is having issues, replacing it usually costs less than repairing it.” Tell us the age if you know it. An old heater that is also leaking at the base meets both of Rheem’s tests above.
Replacing it? The buying side is its own guide.
If you have a boiler, the indirect tank and the tankless heater are both on the table. We compare them there so this page does not have to.
What a technician does on a water heater repair call in Wolcott, Prospect or Cheshire
Each maker prints an order for the technician, and it shows what a visit covers. On an electric tank that is the Bradford White plan above: voltage and the high limit first, then elements, then thermostats. On a gas tank the Bradford White service manual charts run from gas supply and line pressure through the pilot, thermocouple and safety switches, with the combustion air and flame arrestor checked when a heater shuts down on its own. On a tankless unit it is the code history and then the maker’s sequence, which on a Rinnai code 11 runs from gas on and air purged to inlet gas pressure, the igniter spark and the flame rod (Rinnai diagnostic codes guide). On an indirect it is the boiler call, the circulator and zone, and the tank’s thermostat before the coil.
When you call 203-756-5040, have four things ready: the type of heater and the model on its label, any code on the display, whether the boiler is running and the house is heating, and whether there is water on the floor. A real person answers around the clock. We work on tank, tankless and indirect heaters across the Greater Waterbury area, and Wolcott, Prospect and Cheshire are all inside it.
Frequently asked questions
Why is my electric water heater not making hot water?
Start with the breaker or fuse, which both A. O. Smith and Rheem list first. If the power is on, the red high-limit button may have tripped, which means the tank overheated. Elements, thermostats and wiring are service-call parts, and a button that keeps tripping is a reason to book a repair.
Can I press the red reset button on my water heater?
A. O. Smith’s guide says an owner can, with the power disconnected first and the access cover off. Rheem says a qualified technician must investigate the cause before the heater goes back in service. If it trips a second time, stop pressing it and call. A. O. Smith’s own page says repeated tripping points to shorted elements or faulty thermostats.
My tankless water heater shows an error code. What do I do?
Write the code down and try the one reset your manual allows. On the Navien NPE that is a press of the Back button. If the code comes back, or it names gas, ignition, flame or venting, call and read it to us. Rinnai’s code table warns that consumers should not attempt checks they are not qualified to perform.
Why is my boiler-fed indirect heater not making hot water?
Bradford White’s guide starts with the boiler: it has to be running and the circulator has to move water to the tank. If the whole house is cold, read our boiler guide. If only the hot water is missing, the circulator, zone valve, tank thermostat or coil is next, and that is a call.
Is rusty hot water a sign I need a new water heater?
Not by itself. A. O. Smith’s bulletin says the most common cause is iron bacteria and that a tank lining failure big enough to color the water is rare. A leak at the bottom of the tank is different: Rheem says it often signals tank corrosion that requires replacement. Tell us where the rust shows up.
Do you repair water heaters in Wolcott, Prospect and Cheshire?
Yes. All three towns are in our service area from the shop in Watertown, we work on tank, tankless and indirect heaters, and a real person answers 203-756-5040 around the clock for emergencies. Our water heater services page lists what we install, maintain and repair.
No hot water right now?
Call and tell us the heater type, the model and what you see. Family owned in Watertown since 1978. Licensed in Connecticut, HTG.0386984 and SHM.0005083.
Reach the 24/7 lineRelated reading
About the author
American Heating and Air Conditioning Service
Family owned HVAC contractor, 1114 Middlebury Rd, Watertown CT 06795
We have installed and serviced furnaces, boilers and water heaters across the Greater Waterbury area since 1978, our technicians are NATE certified, and we answer the phone 24 hours a day for emergencies. Questions about anything in this article? Call us at 203-756-5040.
References and photo credits
- A. O. Smith, Residential Electric Water Heater Installation Instructions and Use and Care Guide (part 321249-000)
- A. O. Smith, Is Your Hot Water Not Getting Hot? Common Causes and What To Do About Them
- A. O. Smith, Technical Bulletin 21, Discolored Water
- Rheem, Use and Care Manual, Electric Residential Water Heaters with Electronic Control (AP21980 Rev 02)
- Rheem, Use and Care Manual, Residential Gas FVIR Certified Water Heaters (AP23059 Rev 01), hosted in Rheem’s product-document library
- Rheem, What to Do Before Calling a Plumber or Replacing Your Water Heater
- Bradford White, Residential Electric Water Heaters Service Manual (238-51544-00D, rev. 5/22)
- Bradford White, Defender Safety System Flammable Vapor Ignition Resistant Water Heaters Service Manual (238-51542-00E, rev. 08/22)
- Bradford White, Double-Wall Indirect-Fired Water Heater Installation and Operation Instruction Manual with Troubleshooting Guide (238-45085-00K, rev. 10/23)
- Lochinvar, Squire Indirect Water Heater Installation and Operation Manual, models SIT030 to SIT119 (Rev X)
- Rinnai, Tankless Water Heater (Residential) Installation and Operation Manual, N Series, U334-0771(02), sections 4.5 and 5.1
- Rinnai, Troubleshooting Tankless Water Heater Diagnostic Codes (100000652)
- Navien, NPE Condensing Water Heaters User’s Information Manual (NPE-180A2, NPE-210A2, NPE-240A2 and the S2 models), sections 3.3, 5.1 and 5.2
- Navien, NPE-A2 Series FAQs
- Connecticut Public Utilities Regulatory Authority, What To Do If You Smell Natural Gas
- U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center
References checked October 14, 2026. General homeowner information, not a substitute for the instructions supplied with your equipment or an on-site diagnosis. Manual wording differs by model and revision; the documents above are the ones quoted, and your heater’s own manual is the one that governs it.
The hero is an editorial image generated from one of the company’s own job photos; it is not a photograph of a specific customer’s home. All other photos are American Heating and Air Conditioning Service job photos from the company’s own library.
Heating services from American Heating
The pages behind this post, for when the water heater is the next job on the list.
- Water heater repair, maintenance and installation, tank and tankless
- Boiler repair, service and installation, the heat source behind an indirect heater
- Heating services for the Greater Waterbury area, furnaces, boilers and more
- Contact us for 24/7 emergency service, or call 203-756-5040
Heating tips in your inbox
One short email when we publish a new guide for Greater Waterbury homeowners. No sales blasts. Unsubscribe anytime.